Find Electric Wire Single Solid Wire, Nylon Coated Wire, Wire Electric Copper Wire on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Electric Wire Single Solid Wire > Nym-J Electrical Cable 3*2.5mm2 in Gray Color

Nym-J Electrical Cable 3*2.5mm2 in Gray Color

Basic Info

Model No.:  NYM-J

Product Description

Model NO.: NYM-J Conductor Type: Solid Conductor Material: Copper Insulation Material: PVC Range of Application: Refractory Brand: Permanent Test Voltage: 300/500 Volts Type: Insulated Application: Under Plaster, Benton, Brickwork and Concrete Sheath Material: PVC Material Shape: Re/RM Certification: ISO9001, CE, UL, CCC, RoHS, VDE Working Voltage: 300/500 Volts NYM-J is a VDE approved, solid conductor*, gray PVC jacketed, 300/500 volt fixed installation cable. These cables are suitable for use in, on and under plaster, benton, brickwork and concrete. NYM-J cables should not be used in the direct laying of shaken, vibrated or compressed concrete. Outdoor usage is only possible as long as the cable is 
protected against direct sunlight. Usable in the open air, dry, damp and wet environments.
                                                                                              
 
Electricity Cable VGV 3X2.5
Size: 3x2.5mm2
Type: NYM-J
Color: Gray
Conductor: solid Cu wires class 1 acc. VDE 0295 (IEC 60228)
Insulation: PVC type YI1 acc. VDE0207
Core identification:according to VDE 0293
Inner sheat: plastic filling compound
Sheat:PVC type YM1 acc. VDE 0207
Conductor resistance at 20 °C :According to VDE 0295 class 1 (IEC60228)
Max. conductor temperature:70 °C
Max. short circuit temperature:160 °C, not more than 5 sec
Rated voltage Uo/U:300/500 V
Test voltage :AC - 2 kV 50 Hz
Bending radius, min.:6 x D cable
Flame test: VDE 0472 part 804 class B (IEC 332 part 1)
Outer diameter approx.: 11mm
Cu weight approx.: 68kg/km
Cableweight approx.:204kg/km
 
Description & No. Conductors x cross-sec. mm2 Outer Ø (mm) Copper Weight  Weight  AWG
kg/km kg/km
NYM-J 1G1.5 RE 5.4 14.4 40 16
NYM-O 1X1.5 RE 5.4 14.4 40 16
NYM-O 2X1.5 RE 8.7 29 170 16
NYM-J 3G1.5 RE 9.1 43 135 16
NYM-O 3X1.5 RE 9.1 43 135 16
NYM-J 4G1.5 RE 9.8 58 160 16
NYM-O 4X1.5 RE 9.8 58 160 16
NYM-J 5G1.5 RE 10.3 72 190 16
NYM-O 5X1.5 RE 10.3 72 190 16
NYM-J 7G1.5 RE 11.5 101 235 16
NYM-O 7X1.5 RE 11.5 101 235 16
NYM-J 10G1.5 RE 13.8 144 330 16
NYM-J 12G1.5 RE 14.4 173 405 16
NYM-J 1G2.5 RE 6 24 70 14
NYM-O 1X2.5 RE 6 24 70 14
NYM-J 3G2.5 RE 10.4 72 190 14
NYM-O 3X2.5 RE 10.4 72 190 14
NYM-J 4G2.5 RE 11.3 96 230 14
NYM-O 4X2.5 RE 11.3 96 230 14
NYM-J 5G2.5 RE 12 120 270 14
NYM-O 5X2.5 RE 12 120 270 14
NYM-J 7G2.5 RE 13.2 168 342 14
NYM-J 1G4 RE 6.6 38 80 12
NYM-O 1X4 RE 6.6 38 80 12
NYM-J 3G4 RE 12 115 258 12
NYM-J 4G4 RE 13 154 330 12
NYM-O 4X4 RE 13 154 330 12
NYM-J 5G4 RE 14.5 192 410 12
NYM-O 5X4 RE 14.5 192 410 12
NYM-J 1G6 RE 7.2 58 105 10
NYM-O 1X6 RE 7.2 58 105 10
NYM-J 3G6 RE 13 173 320 10
NYM-J 4G6 RE 15.1 230 460 10
NYM-O 4X6 RE 15.1 230 460 10
NYM-J 5G6 RE 16.1 288 540 10
NYM-O 5X6 RE 16.1 288 540 10
Description & No. Conductors x cross-sec. mm2 Outer Ø (mm) Copper Weight  Weight  AWG
kg/km kg/km
NYM-J 1G10 RE 8.4 96 155 8
NYM-O 1X10 RE 8.4 96 155 8
NYM-J 4G10 RE 17.6 384 680 8
NYM-O 4X10 RE 17.6 384 680 8
NYM-J 5G10 RE 19.2 480 850 8
NYM-O 5X10 RE 19.2 480 850 8
NYM-J 1G16 RM 9.9 154 230 6
NYM-O 1X16 RM 9.9 154 230 6
NYM-J 4G16 RM 21.3 614 1048 6
NYM-O 4X16 RM 21.3 614 1048 6
NYM-J 5G16 RM 23.4 768 1280 6
NYM-O 5X16 RM 23.4 768 1280 6
NYM-J 1G25 RM 12 240 325 4
NYM-J 4G25 RM 25.8 960 1649 4
NYM-O 4X25 RM 25.8 960 1649 4
NYM-J 5G25 RM 28.7 1200 1970 4
NYM-J 4G35 RM 28.5 1344 2000 2
NYM-O 4X35 RM 28.5 1344 2000 2
 
 
 
Technical Data  
PVC-outer jacket cable to DIN VDE 0250 part 204
Temperature Range
Flexing 
+5°C to +70°C (+41°F to +158°F)
Fixed Installation 
-40°C to +70°C (-40°F to +158°F)
Nominal Voltage
U0/U 300/500 V Test Voltage 2000 V
Minimum Bending Radius
Fixed Installation 6x cable Ø
Radiation Resistance
Up to 80x106 cJ/kg (up to 80 Mrad)
Caloric Load Values
See Technical Information  
 
 
Cable Construction  
Solid or stranded, plain copper conductor to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 2
PVC conductor insulation, TI1 to DIN VDE 0281 part 1
Color coded to DIN VDE 0293-308
Conductors stranded in layer
Special PVC outer jacket TM1, to DIN VDE 0281 part 1
Jacket color: Gray (RAL 7035)  
Application  
For industrial and wiring purposes. 
Useable in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in cement, not suitable for imbedding in solidified or compressed concrete. Outdoor use is only possible as long as the cable is protected against direct sunlight. 
The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
 
 
Properties  
PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Note  
RE = round conductor, single-wire
RM = round conductor, multiple-wire
G = with green-yellow grounding
x = without green-yellow grounding (OZ)
AWG sizes are approximate equivalent values. The actual cross-section is in mm².  
 

Contact us if you need more details on Nym Cable. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vgv Cable、Nym-J Cable. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Electric Wire Single Solid Wire

Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters